1 What is the typical payback time of installing an economiser in a boiler system?

Question 6 of 6 Advanced

Happy with your answers?

Submit your current answers and get the final test result.

Submit

Test results

Congratulations. You have passed the test and completed the Boiler systems

Achieved badges:

Continue training Go to MyECADEMY

Sorry. You did not pass the Boiler systems test this time

Correct
01.
Q: What is the typical payback time of installing an economiser in a boiler system?
A: Less than two years.
Correct
02.
Q: What is direct boiler feed?
A: Variable speed pumps equipped with level sensors to control the water level
Correct
03.
Q: Why are feed valves problematic?
A: Valves cause pressure loss, which increases energy consumption and requires larger pumps
Correct
04.
Q: Why is chemical treatment of the make-up water necessary?
A: To prevent scaling in the boiler and the water from turning acidic when heated.
Correct
05.
Q: When does cavitation in the feed pumps occur?
A: Cavitation occurs when the pressure in the first impeller or pipes drops below the vapour pressure of the water.
Correct
06.
Q: How does an economiser work?
A: In an economiser flue gas is led past a network of pipes with cold water, transferring heat from the flue gas to the water.