Question 1 of 6 Advanced

Where can you find the required cooling level?

Question 2 of 6 Advanced

Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?

Question 4 of 6 Advanced

At which stage does Grundfos recommend installing an output filter?

Question 5 of 6 Advanced

What is a general rule of thumb when it comes to a motor cable?

Question 6 of 6 Advanced

Which type of output filter does Grundfos recommend?

Question 6 of 6 Advanced

Happy with your answers?

Submit your current answers and get the final test result.

Submit

Test results

Congratulations. You have passed the test and completed the 26 - The SP submersible pump

Achieved badges:

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Continue training Go to MyECADEMY

Sorry. You did not pass the 26 - The SP submersible pump test this time

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Correct
Q: Where can you find the required cooling level?
A: On the motor nameplate
Correct
Q: Which of these three parameters isn’t essential in terms of gaining an optimal motor protection?
A: Motor power
Correct
Q: When does undervoltage typically happen?
A: When the drop cables are too small
Correct
Q: At which stage does Grundfos recommend installing an output filter?
A: If the net supply is over 380 V
Correct
Q: What is a general rule of thumb when it comes to a motor cable?
A: It must always be submerged in liquid
Correct
Q: Which type of output filter does Grundfos recommend?
A: Sine wave filter