- Grundfos Canada
- Learn
- Ecademy
- All courses
- 13 - Basic hydraulics and p...
- Test your knowledge
Question 1 of 8
Basic
Which of the following is one correct method to avoid cavitation?
Question 2 of 8
Basic
What are the effects of cavitation on pumps?
Question 3 of 8
Basic
Which of the following items are built-in in some motors and can stop the motor if it exceeds a preset temperature:
Question 4 of 8
Basic
Identify the reasons for reduction in pump performance from the given options:
Question 5 of 8
Basic
Select the three parameters of most interest in water pumping systems:
Question 6 of 8
Basic
Friction loss is dependent on the [xxxxxxxx] of the fluid.
Question 7 of 8
Basic
How can friction loss in a system be minimised?
Question 8 of 8
Basic
What causes cavitation?
Question 8 of 8
Basic
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 13 - Basic hydraulics and pump performance
Sorry. You did not pass the 13 - Basic hydraulics and pump performance test this time
Achieved badges:
How would you rate this course?
1: Which of the following is one correct method to avoid cavitation?
Reduce the friction loss in the suction pipe.
1: Which of the following is one correct method to avoid cavitation?
Increase the flow of the pump.
You can find the answer here >
1: Which of the following is one correct method to avoid cavitation?
Lower the elevation of the suction water level.
You can find the answer here >
2: What are the effects of cavitation on pumps?
Breakage of rotor
You can find the answer here >
2: What are the effects of cavitation on pumps?
Pitting of suction pipe
You can find the answer here >
2: What are the effects of cavitation on pumps?
Pitting of impeller and pump housing
3: Which of the following items are built-in in some motors and can stop the motor if it exceeds a preset temperature:
Temperature sensors
3: Which of the following items are built-in in some motors and can stop the motor if it exceeds a preset temperature:
Signal wire
You can find the answer here >
3: Which of the following items are built-in in some motors and can stop the motor if it exceeds a preset temperature:
Insulation system
You can find the answer here >
4: Identify the reasons for reduction in pump performance from the given options:
Bad power supply
4: Identify the reasons for reduction in pump performance from the given options:
Reduction in size of irrigation zone
You can find the answer here >
4: Identify the reasons for reduction in pump performance from the given options:
Changes in energy requirements
You can find the answer here >
5: Select the three parameters of most interest in water pumping systems:
Flow, head and energy
5: Select the three parameters of most interest in water pumping systems:
Flow, conductivity and head
You can find the answer here >
5: Select the three parameters of most interest in water pumping systems:
Head, turbidity and velocity
You can find the answer here >
6: Friction loss is dependent on the [xxxxxxxx] of the fluid.
Viscosity
You can find the answer here >
6: Friction loss is dependent on the [xxxxxxxx] of the fluid.
Velocity
6: Friction loss is dependent on the [xxxxxxxx] of the fluid.
7: How can friction loss in a system be minimised?
By increasing the pipe diameter
7: How can friction loss in a system be minimised?
By using 2 smaller pumps instead of one bigger pump
You can find the answer here >
7: How can friction loss in a system be minimised?
By adding a Tee to the piping system
You can find the answer here >
8: What causes cavitation?
Cavitation occurs when water changes its state from vapour to water at low pressure.
8: What causes cavitation?
Cavitation occurs when water boils at 212°F and changes its state from water to vapour at normal atmospheric pressure.
You can find the answer here >
8: What causes cavitation?
Cavitation occurs when water flows through a pipe and a valve is closed quickly at a low atmospheric pressure
You can find the answer here >