Question 1 of 6
Basic

What is the FLOWADAPT control mode?

Question 2 of 6
Basic

If there is an internal sensor fault in the pump, which arrow do you press?

Question 3 of 6
Basic

How does MAGNA3 communicate?

Question 4 of 6
Basic

What does the FLOWADAPT control mode reduce the need for?

Question 5 of 6
Basic

What does a yellow indicator in the Grundfos Eye mean?

Question 6 of 6
Basic

When do you use the constant flow control mode?

Question 6 of 6
Basic

Happy with your answers?

Submit your current answers and get the final test result.

Test results

Congratulations. You have passed the test and completed the 60 - The MAGNA3 Circulator Pump Course
Sorry. You did not pass the 60 - The MAGNA3 Circulator Pump Course test this time
Achieved badges:
How would you rate this course?
1: What is the FLOWADAPT control mode?
A control mode in which the pump continuously adapts its performance to varying flow and performance demands
You can find the answer here >
1: What is the FLOWADAPT control mode?
A combination of the AUTOADAPT control mode and the flowlimit control function
1: What is the FLOWADAPT control mode?
A control mode in which the pump automatically sets a proportional pressure curve with a setpoint of 55%
You can find the answer here >
2: If there is an internal sensor fault in the pump, which arrow do you press?
2: If there is an internal sensor fault in the pump, which arrow do you press?
2: If there is an internal sensor fault in the pump, which arrow do you press?
The left arorw
3: How does MAGNA3 communicate?
3: How does MAGNA3 communicate?
3: How does MAGNA3 communicate?
Via wireless radio
4: What does the FLOWADAPT control mode reduce the need for?
It reduces the need for pump throttling valves
4: What does the FLOWADAPT control mode reduce the need for?
It reduces the need for manual balancing
You can find the answer here >
4: What does the FLOWADAPT control mode reduce the need for?
It reduces the need for maintenance
You can find the answer here >
5: What does a yellow indicator in the Grundfos Eye mean?
5: What does a yellow indicator in the Grundfos Eye mean?
The pump has a warning but can continue
5: What does a yellow indicator in the Grundfos Eye mean?
The pump is slightly damaged but it can continue
You can find the answer here >
6: When do you use the constant flow control mode?
In systems that demand constant flow independent of pressure losses
6: When do you use the constant flow control mode?
In commercial buildings and small family homes
You can find the answer here >
6: When do you use the constant flow control mode?
Nowhere - it's a made-up control mode
You can find the answer here >