Question 1 of 6
Intermediate

Pump energy savings in a distributed pumping system are around:

Question 2 of 6
Intermediate

Why is coil flow always correct in a distributed pumping system?

Question 3 of 6
Intermediate

With a Distributed Pumping system, does commissioning and balancing

Question 4 of 6
Intermediate

Why is there in most cases no bypass flow with a distributed pumping system?

Question 5 of 6
Intermediate

How does the MPC controller protect chillers from freezing?

Question 6 of 6
Intermediate

What is the benefit of aligning primary side flow with secondary side flow?

Question 6 of 6
Intermediate

Happy with your answers?

Submit your current answers and get the final test result.

Test results

Congratulations. You have passed the test and completed the 69 - The Grundfos Distributed Pumping Course
Sorry. You did not pass the 69 - The Grundfos Distributed Pumping Course test this time
Achieved badges:
How would you rate this course?
1: Pump energy savings in a distributed pumping system are around:
1: Pump energy savings in a distributed pumping system are around:
1: Pump energy savings in a distributed pumping system are around:
54%
2: Why is coil flow always correct in a distributed pumping system?
By using large variable speed-controlled primary pumps
You can find the answer here >
2: Why is coil flow always correct in a distributed pumping system?
Because Magna 3 pump speed is modulated based on terminal unit load
2: Why is coil flow always correct in a distributed pumping system?
Because the system runs with maximum flow at maximum load
You can find the answer here >
3: With a Distributed Pumping system, does commissioning and balancing
3: With a Distributed Pumping system, does commissioning and balancing
3: With a Distributed Pumping system, does commissioning and balancing
Is done quickly and easily
4: Why is there in most cases no bypass flow with a distributed pumping system?
Because primary pumps try to match primary flow and secondary flow
4: Why is there in most cases no bypass flow with a distributed pumping system?
The bypass valve is always closed
You can find the answer here >
4: Why is there in most cases no bypass flow with a distributed pumping system?
The system is never over-pumped
You can find the answer here >
5: How does the MPC controller protect chillers from freezing?
By fulfilling the chiller setpoint signal
You can find the answer here >
5: How does the MPC controller protect chillers from freezing?
By ensuring minimum flow over the active chille
5: How does the MPC controller protect chillers from freezing?
By chiller temperature signal
You can find the answer here >
6: What is the benefit of aligning primary side flow with secondary side flow?
To ensure distributed pumps never miss water on the suction side
You can find the answer here >
6: What is the benefit of aligning primary side flow with secondary side flow?
To avoid increasing pressure in the bypass pipe
You can find the answer here >
6: What is the benefit of aligning primary side flow with secondary side flow?
To avoid or minimise the ‘low’ Delta T syndrome