- Grundfos Hong Kong
- Learn
- Ecademy
- All courses
- 19 - Prefabricated Pumping ...
- Test your knowledge
Question 1 of 6
Advanced
Up to how many pumps can Grundfos Dedicated Controls control?
Question 2 of 6
Advanced
Where is the submerged to dry installation placed?
Question 3 of 6
Advanced
What does it mean that the CUE frequency converter is pre-programmed?
Question 4 of 6
Advanced
How are inlet pipes added to the PS.R stations?
Question 5 of 6
Advanced
What is the max. diameter of a PS.G. station?
Question 6 of 6
Advanced
What does an IO 113 sensor module do?
Question 6 of 6
Advanced
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 19 - Prefabricated Pumping Stations
Sorry. You did not pass the 19 - Prefabricated Pumping Stations test this time
Achieved badges:
How would you rate this course?
1: Up to how many pumps can Grundfos Dedicated Controls control?
1: Up to how many pumps can Grundfos Dedicated Controls control?
1: Up to how many pumps can Grundfos Dedicated Controls control?
6
2: Where is the submerged to dry installation placed?
In the top of the old pumping station
You can find the answer here >
2: Where is the submerged to dry installation placed?
It replaces the old pumping station
You can find the answer here >
2: Where is the submerged to dry installation placed?
In a separate hole next to the old pumping station
3: What does it mean that the CUE frequency converter is pre-programmed?
It lets you reduce the pumps’ downtime
You can find the answer here >
3: What does it mean that the CUE frequency converter is pre-programmed?
It lets you protect the motor
You can find the answer here >
3: What does it mean that the CUE frequency converter is pre-programmed?
It lets you reduce commissioning time significantly
4: How are inlet pipes added to the PS.R stations?
In-laminated from factory
You can find the answer here >
4: How are inlet pipes added to the PS.R stations?
Added on site with a holedril
4: How are inlet pipes added to the PS.R stations?
In-laminated on site
You can find the answer here >
5: What is the max. diameter of a PS.G. station?
5: What is the max. diameter of a PS.G. station?
3000mm
5: What is the max. diameter of a PS.G. station?
6: What does an IO 113 sensor module do?
It protects the motor
6: What does an IO 113 sensor module do?
Adjust pump speed according to demand
You can find the answer here >
6: What does an IO 113 sensor module do?
It’s an internet-based monitoring system
You can find the answer here >