Question 1 of 8
Intermediate
What are constant pressure control modes mainly used for with an ALPHA2?
Question 2 of 8
Intermediate
Which control modes should never be used in systems with TRVs?
Question 3 of 8
Intermediate
When balancing a combined radiator and underfloor heating system you should always:
Question 4 of 8
Intermediate
Which of the following benefits does not apply to ALPHA2?
Question 5 of 8
Intermediate
What is the primary advantage of using the ALPHA Reader and the Grundfos GO Balance app in balancing jobs in one-family homes?
Question 6 of 8
Intermediate
What typically causes imbalance in one-family homes?
Question 7 of 8
Intermediate
Is it possible to generate documentation and email or print it directly from the app?
Question 8 of 8
Intermediate
If you need to balance both the radiator and the underfloor heating system in a combined system, how many ALPHA2 pumps must be installed?
Question 8 of 8
Intermediate
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 39 - The ALPHA2 circulator pump and easy balancing with the GO Balance app
Sorry. You did not pass the 39 - The ALPHA2 circulator pump and easy balancing with the GO Balance app test this time
Achieved badges:
How would you rate this course?
1: What are constant pressure control modes mainly used for with an ALPHA2?
Boilers
You can find the answer here >
1: What are constant pressure control modes mainly used for with an ALPHA2?
Radiators
You can find the answer here >
1: What are constant pressure control modes mainly used for with an ALPHA2?
Underfloor Heating
2: Which control modes should never be used in systems with TRVs?
Fixed speed modes
2: Which control modes should never be used in systems with TRVs?
Constant pressure modes
You can find the answer here >
2: Which control modes should never be used in systems with TRVs?
Proportional pressure modes
You can find the answer here >
3: When balancing a combined radiator and underfloor heating system you should always:
Balance all radiators in the system first
3: When balancing a combined radiator and underfloor heating system you should always:
Balance one room at a time regardless of the type of heat supply in the room
You can find the answer here >
3: When balancing a combined radiator and underfloor heating system you should always:
Balance all zones in the underfloor heating system first
You can find the answer here >
4: Which of the following benefits does not apply to ALPHA2?
Easy hydronic balancing
You can find the answer here >
4: Which of the following benefits does not apply to ALPHA2?
No blockage
You can find the answer here >
4: Which of the following benefits does not apply to ALPHA2?
Universal application
5: What is the primary advantage of using the ALPHA Reader and the Grundfos GO Balance app in balancing jobs in one-family homes?
They optimise the performance of the ALPHA2 circulator
You can find the answer here >
5: What is the primary advantage of using the ALPHA Reader and the Grundfos GO Balance app in balancing jobs in one-family homes?
It only takes two hours to balance each radiator
You can find the answer here >
5: What is the primary advantage of using the ALPHA Reader and the Grundfos GO Balance app in balancing jobs in one-family homes?
Balancing of all radiators can be completed in less than two hours
6: What typically causes imbalance in one-family homes?
Pressure loss and/or incorrectly set valves
6: What typically causes imbalance in one-family homes?
Over-sized pumps
You can find the answer here >
6: What typically causes imbalance in one-family homes?
Poor indoor climate
You can find the answer here >
7: Is it possible to generate documentation and email or print it directly from the app?
Yes
7: Is it possible to generate documentation and email or print it directly from the app?
8: If you need to balance both the radiator and the underfloor heating system in a combined system, how many ALPHA2 pumps must be installed?
One ALPHA2 that runs the radiator system
You can find the answer here >
8: If you need to balance both the radiator and the underfloor heating system in a combined system, how many ALPHA2 pumps must be installed?
One ALPHA2 that runs the radiator system and one ALPHA2 that runs the underfloor heating system
8: If you need to balance both the radiator and the underfloor heating system in a combined system, how many ALPHA2 pumps must be installed?
One ALPHA2 that runs the underfloor heating system
You can find the answer here >