8 questions Intermediate

ECADEMY test

17 - Groundwater Pumping

This course test contains 8 questions and can be retaken at any time.

You must answer all questions correctly to pass the test and complete the course.

Start test

Question 1 of 8 Intermediate

What should the minimum flow past the motor be to ensure sufficient motor cooling?

Question 3 of 8 Intermediate

How does over- and under voltage, phase unbalance and phase loss impact the pump motor?

Question 4 of 8 Intermediate

What kind of riser pipe is most likely to keep itself free from scaling?

Question 5 of 8 Intermediate

In which areas is there a bigger risk of pumping corrosive groundwater?

Question 6 of 8 Intermediate

By-pass control is an efficient way of performance regulating a pump but what is the downside of the process?

Question 7 of 8 Intermediate

On top of energy-efficient pump operation, how does a frequency drive benefit your installation?

Question 8 of 8 Intermediate

What is the most effective way to stay updated on your pump’s condition?

Question 8 of 8 Intermediate

Happy with your answers?

Submit your current answers and get the final test result.

Submit

Test results

Congratulations. You have passed the test and completed the 17 - Groundwater Pumping

Achieved badges:

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Continue training Go to MyECADEMY

Sorry. You did not pass the 17 - Groundwater Pumping test this time

How would you rate this course?

You are welcome to add your rating of this course. Remember that you have to be logged in before you take the test to be able to give your rating.

Correct
Q: What should the minimum flow past the motor be to ensure sufficient motor cooling?
A: 0,15 m/s
Correct
Q: What is well development?
A: A process that ensures that the well’s sand filter has been improved so the well produces clean, sand-free water
Correct
Q: How does over- and under voltage, phase unbalance and phase loss impact the pump motor?
A: It raises the motor temperature, reducing the lifetime
Correct
Q: What kind of riser pipe is most likely to keep itself free from scaling?
A: Flex hoses
Correct
Q: In which areas is there a bigger risk of pumping corrosive groundwater?
A: In coastal areas
Correct
Q: By-pass control is an efficient way of performance regulating a pump but what is the downside of the process?
A: Energy is wasted as the pump continues to run at full speed
Correct
Q: On top of energy-efficient pump operation, how does a frequency drive benefit your installation?
A: It comes with a built-in motor protection
Correct
Q: What is the most effective way to stay updated on your pump’s condition?
A: Remote online monitoring