Question 1 of 6
Intermediate
Is the SQE pump able to provide constant pressure?
Question 2 of 6
Intermediate
How many times higher than nominal speed does the motor current reach during the first milliseconds?
Question 3 of 6
Intermediate
Why is it important to protect the pump from over- and under voltage?
Question 4 of 6
Intermediate
By how much does the supply voltage decrease before the motor contactor stops the pump?
Question 5 of 6
Intermediate
Why must the pump unit be installed below the dynamic water table?
Question 6 of 6
Intermediate
What is the most commonly used starting method for motors in 4” conventional pumps?
Question 6 of 6
Intermediate
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 37 - Grundfos SQ/SQE
Sorry. You did not pass the 37 - Grundfos SQ/SQE test this time
Achieved badges:
How would you rate this course?
1: Is the SQE pump able to provide constant pressure?
1: Is the SQE pump able to provide constant pressure?
Yes.
2: How many times higher than nominal speed does the motor current reach during the first milliseconds?
Four times higher
You can find the answer here >
2: How many times higher than nominal speed does the motor current reach during the first milliseconds?
Six times higher
You can find the answer here >
2: How many times higher than nominal speed does the motor current reach during the first milliseconds?
Seven times higher
3: Why is it important to protect the pump from over- and under voltage?
Because large variations in power supply will damage the motor over time.
3: Why is it important to protect the pump from over- and under voltage?
To avoid burning the house fuses.
You can find the answer here >
3: Why is it important to protect the pump from over- and under voltage?
To minimise the power consumption.
You can find the answer here >
4: By how much does the supply voltage decrease before the motor contactor stops the pump?
More than 10 %
4: By how much does the supply voltage decrease before the motor contactor stops the pump?
More than 15 %
You can find the answer here >
4: By how much does the supply voltage decrease before the motor contactor stops the pump?
More than 20 %
You can find the answer here >
5: Why must the pump unit be installed below the dynamic water table?
So you are sure to minimise your power bill.
You can find the answer here >
5: Why must the pump unit be installed below the dynamic water table?
To avoid the risk of dry-running during operation.
5: Why must the pump unit be installed below the dynamic water table?
To maintain a stable pressure in the system.
You can find the answer here >
6: What is the most commonly used starting method for motors in 4” conventional pumps?
Direct on line
6: What is the most commonly used starting method for motors in 4” conventional pumps?
Star delta starters
You can find the answer here >
6: What is the most commonly used starting method for motors in 4” conventional pumps?
Auto transformer
You can find the answer here >