Vraag 1 van 8
Gemiddeld

What are the four most common types of wastewater from commercial buildings?

Vraag 2 van 8
Gemiddeld

Who has the financial responsibility in the case of flooding in most countries?

Vraag 3 van 8
Gemiddeld

Which treatment is necessary for storm water?

Vraag 4 van 8
Gemiddeld

What are the disadvantages of the traditional gravitation system?

Vraag 5 van 8
Gemiddeld

Why is the life cycle cost of the pressurised wastewater system low?

Vraag 6 van 8
Gemiddeld

Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection: Is not sensitive to fat, grease, sands and solids in the water. Makes it possible to use sanitary facilities in case of backflow. Offers protection for paved areas. Can be connected to buildings’ storm water drains.

Vraag 7 van 8
Gemiddeld

Of the three anti-flooding systems, why is the lifting station the superior system?

Vraag 8 van 8
Gemiddeld

Which three factors have increased the risk of flooding and back flow?

Vraag 8 van 8
Gemiddeld

Tevreden met uw antwoorden?

Vul jouw huidige antwoorden in en ontvang het definitieve testresultaat.

Resultaten van de test

Gefeliciteerd. U bent geslaagd voor de test en heeft de cursus voltooid 3 - Afvalwater in gebouwen
Sorry. U heeft het niet gehaald 3 - Afvalwater in gebouwen Test deze keer
Behaalde badges:
Wat voor beoordeling geeft u deze cursus?
1: What are the four most common types of wastewater from commercial buildings?
Wastewater, storm water, drainage water and wastewater from parking areas
1: What are the four most common types of wastewater from commercial buildings?
Rainwater, wastewater, storm water and drainage water
U vindt het antwoord hier >
1: What are the four most common types of wastewater from commercial buildings?
Wastewater, storm water, air-conditioning wastewater and wastewater from parking areas
U vindt het antwoord hier >
2: Who has the financial responsibility in the case of flooding in most countries?
The building owner and the building designers
2: Who has the financial responsibility in the case of flooding in most countries?
The government and the wastewater authorities
U vindt het antwoord hier >
2: Who has the financial responsibility in the case of flooding in most countries?
The building designers and the contractors
U vindt het antwoord hier >
3: Which treatment is necessary for storm water?
It has to go through an oil/petrol separator
U vindt het antwoord hier >
3: Which treatment is necessary for storm water?
It has to go through a sand pressure
U vindt het antwoord hier >
3: Which treatment is necessary for storm water?
None – it is pumped directly to the recipient
4: What are the disadvantages of the traditional gravitation system?
Many gravitation pipes with a small diameter have to be installed outside the building and the inspection wells are expensive
U vindt het antwoord hier >
4: What are the disadvantages of the traditional gravitation system?
Inspection wells are difficult to maintain and the initial cost of the pumping pit is high
U vindt het antwoord hier >
4: What are the disadvantages of the traditional gravitation system?
Many gravitation pipes have to be installed outside the building and a great deal of excavation work is needed.
5: Why is the life cycle cost of the pressurised wastewater system low?
There are only a few gravitation pipes outside the building and the excavation cost is low
U vindt het antwoord hier >
5: Why is the life cycle cost of the pressurised wastewater system low?
The initial cost of the lifting station is lower compared with a pit and there are no gravitation pipes outside the building
5: Why is the life cycle cost of the pressurised wastewater system low?
The lifting station and the pipe system is maintenance-free
U vindt het antwoord hier >
6: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection: Is not sensitive to fat, grease, sands and solids in the water. Makes it possible to use sanitary facilities in case of backflow. Offers protection for paved areas. Can be connected to buildings’ storm water drains.
Anti-flooding valves
U vindt het antwoord hier >
6: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection: Is not sensitive to fat, grease, sands and solids in the water. Makes it possible to use sanitary facilities in case of backflow. Offers protection for paved areas. Can be connected to buildings’ storm water drains.
Pumping stations
6: Which method of backflow prevention has the following advantages: Offers maximum backflow and flooding protection: Is not sensitive to fat, grease, sands and solids in the water. Makes it possible to use sanitary facilities in case of backflow. Offers protection for paved areas. Can be connected to buildings’ storm water drains.
7: Of the three anti-flooding systems, why is the lifting station the superior system?
It is located outside the building which means bad odour is never a problem
U vindt het antwoord hier >
7: Of the three anti-flooding systems, why is the lifting station the superior system?
The storage volume is high and it is easy to assemble and install
U vindt het antwoord hier >
7: Of the three anti-flooding systems, why is the lifting station the superior system?
It is pre-assembled and its location inside the building makes it easily accessible for service. Furthermore, it offers maximum backflow and flooding protection
8: Which three factors have increased the risk of flooding and back flow?
A higher frequency of rainfalls, increased length of rainfalls and more paved areas today than earlier.
8: Which three factors have increased the risk of flooding and back flow?
A higher frequency of rainfalls, unmaintained sewers and an increase in paved areas
U vindt het antwoord hier >
8: Which three factors have increased the risk of flooding and back flow?
A higher frequency of rainfalls and buildings that are poorly equipped for increased amounts of water.
U vindt het antwoord hier >