Question 1 of 6
Intermediate

The 3” SQ pump is obviously ideal for new boreholes but where can it also be used?

Question 2 of 6
Intermediate

Which protection features does the SQE have?

Question 3 of 6
Intermediate

Why is correct sizing of the submersible pump important?

Question 4 of 6
Intermediate

How does the integrated dry-running protection work?

Question 5 of 6
Intermediate

In addition to limiting the current draw from the mains during start-up of the pump, how does the soft-start functionality benefit operation?

Question 6 of 6
Intermediate

How many times higher than nominal speed does the motor current reach during the first milliseconds?

Question 6 of 6
Intermediate

Happy with your answers?

Submit your current answers and get the final test result.

Test results

Congratulations. You have passed the test and completed the 37 - Grundfos SQ/SQE
Sorry. You did not pass the 37 - Grundfos SQ/SQE test this time
Achieved badges:
How would you rate this course?
1: The 3” SQ pump is obviously ideal for new boreholes but where can it also be used?
In wells with water temperature up to 60° C.
You can find the answer here >
1: The 3” SQ pump is obviously ideal for new boreholes but where can it also be used?
In installations that require constant pressure.
You can find the answer here >
1: The 3” SQ pump is obviously ideal for new boreholes but where can it also be used?
In original 4” boreholes where sediments over the years have narrowed the hole.
2: Which protection features does the SQE have?
Voltage handling, soft start, dry-running protection and overload protection.
2: Which protection features does the SQE have?
Protection against the well running dry.
You can find the answer here >
2: Which protection features does the SQE have?
The SQE does not have any protection features.
You can find the answer here >
3: Why is correct sizing of the submersible pump important?
Because an undersized pump will not be able to deliver the required flow and pressure and an oversized pump reduces energy efficiency, which increases operational costs.
3: Why is correct sizing of the submersible pump important?
Because too small a pump will pump the well dry.
You can find the answer here >
3: Why is correct sizing of the submersible pump important?
Because too big a pump will ruin the taps due to too high pressure.
You can find the answer here >
4: How does the integrated dry-running protection work?
It automatically restarts 3 minutes after shut down.
You can find the answer here >
4: How does the integrated dry-running protection work?
It prevents sand from damaging the pump.
You can find the answer here >
4: How does the integrated dry-running protection work?
It automatically shuts down the pump if water shortage is detected.
5: In addition to limiting the current draw from the mains during start-up of the pump, how does the soft-start functionality benefit operation?
Soft start reduces over-pressure in your piping.
You can find the answer here >
5: In addition to limiting the current draw from the mains during start-up of the pump, how does the soft-start functionality benefit operation?
It reduces the occurrence of water hammer in the pipes and minimises wear during start-up.
5: In addition to limiting the current draw from the mains during start-up of the pump, how does the soft-start functionality benefit operation?
Soft start prevents the motor from getting warm.
You can find the answer here >
6: How many times higher than nominal speed does the motor current reach during the first milliseconds?
6: How many times higher than nominal speed does the motor current reach during the first milliseconds?
6: How many times higher than nominal speed does the motor current reach during the first milliseconds?
Seven times higher