Question 1 of 6
Basic
What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
Question 2 of 6
Basic
Which of the following parameters is determined by the amount of water to be applied during the peak period?
Question 3 of 6
Basic
What are the two factors that should be ensured when the total head for a ground water pump is calculated?
Question 4 of 6
Basic
Identify which of the following sentences are true:
Question 5 of 6
Basic
Which of the following options is true about a centrifugal pump?
Question 6 of 6
Basic
Identify the factors that are not considered for calculating the total pump head requirements?
Question 6 of 6
Basic
Happy with your answers?
Submit your current answers and get the final test result.
Test results
Congratulations. You have passed the test and completed the 15 - Pump sizing
Sorry. You did not pass the 15 - Pump sizing test this time
Achieved badges:
How would you rate this course?
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
15ppm
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
2: Which of the following parameters is determined by the amount of water to be applied during the peak period?
The efficiency of the pump
You can find the answer here >
2: Which of the following parameters is determined by the amount of water to be applied during the peak period?
The friction loss in the irrigation system
You can find the answer here >
2: Which of the following parameters is determined by the amount of water to be applied during the peak period?
The minimum size of the pump
3: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no elevation lift and the drawdown has to be added to the suction lift.
You can find the answer here >
3: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no suction lift. Instead there is static water table and the drawdown has to be added to the elevation lift.
3: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no suction lift and the drawdown has to be deducted from the elevation lift.
You can find the answer here >
4: Identify which of the following sentences are true:
Groundwater typically requires more treatment than surface water.
You can find the answer here >
4: Identify which of the following sentences are true:
To improve the filtering function, the borehole diameter must be exactly the same as the casing diameter.
You can find the answer here >
4: Identify which of the following sentences are true:
The drawdown is the difference between the static and the dynamic water level.
5: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a lower flow, it delivers a higher head.
5: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a lower flow, it delivers a lower head.
You can find the answer here >
5: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a higher flow, it delivers a higher head.
You can find the answer here >
6: Identify the factors that are not considered for calculating the total pump head requirements?
Friction losses
You can find the answer here >
6: Identify the factors that are not considered for calculating the total pump head requirements?
Elevation lift
You can find the answer here >
6: Identify the factors that are not considered for calculating the total pump head requirements?
Pump flow