Question: Why is the drainage pump running but not delivering any water?
Answer:
Most common causes:
- Discharge valve closed or blocked → Check and open/clean the valve.
- Nonreturn valve (NRV) blocked → Clean the NRV.
- Air locked in the pump → Lift pump out of water while running to vent, then lower back in.
Additional information:
Need more support? Check out the UNILIFT range course at Ecademy; our free online training tool.