Question 1 of 6
Basic

What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?

Question 2 of 6
Basic

Identify which of the following sentences are true:

Question 3 of 6
Basic

Which of the following options is true about a centrifugal pump?

Question 4 of 6
Basic

How do we calculate head requirement from the pump?

Question 5 of 6
Basic

What are the two factors that should be ensured when the total head for a ground water pump is calculated?

Question 6 of 6
Basic

How many hours will a correctly sized pump run a day to meet the demand?

Question 6 of 6
Basic

Happy with your answers?

Submit your current answers and get the final test result.

Test results

Congratulations. You have passed the test and completed the 15 - Pump sizing
Sorry. You did not pass the 15 - Pump sizing test this time
Achieved badges:
How would you rate this course?
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
15ppm
1: What is the limit of sand in well water as recommended by US EPA and National Water Works Association for flood irrigation?
2: Identify which of the following sentences are true:
Groundwater typically requires more treatment than surface water.
You can find the answer here >
2: Identify which of the following sentences are true:
To improve the filtering function, the borehole diameter must be exactly the same as the casing diameter.
You can find the answer here >
2: Identify which of the following sentences are true:
The drawdown is the difference between the static and the dynamic water level.
3: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a lower flow, it delivers a higher head.
3: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a lower flow, it delivers a lower head.
You can find the answer here >
3: Which of the following options is true about a centrifugal pump?
If the pump is pumping at a higher flow, it delivers a higher head.
You can find the answer here >
4: How do we calculate head requirement from the pump?
Suction lift + static water level + drawdown in the well + pressure head of the application device + friction loss in the pipes
You can find the answer here >
4: How do we calculate head requirement from the pump?
Elevation lift + static water level + drawdown in the well + pressure head of the application device + friction loss in the pipes
4: How do we calculate head requirement from the pump?
Elevation lift + static water level + drawdown in the well + pressure head of the application device - friction loss in the pipes
You can find the answer here >
5: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no elevation lift and the drawdown has to be added to the suction lift.
You can find the answer here >
5: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no suction lift. Instead there is static water table and the drawdown has to be added to the elevation lift.
5: What are the two factors that should be ensured when the total head for a ground water pump is calculated?
There is no suction lift and the drawdown has to be deducted from the elevation lift.
You can find the answer here >
6: How many hours will a correctly sized pump run a day to meet the demand?
6: How many hours will a correctly sized pump run a day to meet the demand?
12-18 hours
6: How many hours will a correctly sized pump run a day to meet the demand?