The NPSH curve displays the minimum required inlet pressure (expressed in meters or feet) allowing the pump to pump in accordance with the performance curve so to avoid cavitation inside the pump at a given flow rate.
The NPSH value available at the pump's suction ports must always be at least 0.5 meters (1.7 feet) greater than the required NPSH value: NPSHA > NPSHR + 0.5 meters (1.7 feet) safety margin.
Additional information:
Enhance your knowledge
Find out how to get reduced energy consumption, increased comfort and unsurpassed operational reliability for your application. Read our customers' stories about how they benefit from the Grundfos approach to intelligence, water and energy, or search Grundfos research & insights for more learning materials, articles, white papers, videos and much more that benefit your solution.